Summary of the experimental parameters and results obtained by PCS, TEM and relaxometry for the study of flow parameters influences.

Capillary Inner Diameter (mm) Flow Rate(mL·min−1) Residence Time
(min)
Diameter NMRD Data Relaxivity Measurements
DPCS (nm) DTEM
(nm)
PDI DNMRD (nm) Ms (A·m²·kg−1) r2/r1
(20 MHz)
r2/r1
(60 MHz)
0.5 0.05 3.93 6.1 3.69 ± 0.81 1.16 6.82 38.4 1.58 2.42
0.5 0.1 1.96 6.2 3.70 ± 0.84 1.14 6.50 41.2 1.54 2.30
0.5 0.5 0.39 8.8 3.70 ± 0.92 1.15 7.18 25.4 1.45 2.26
0.5 1 0.20 6.6 3.61 ± 0.72 1.15 5.82 27 1.40 2.19
0.75 0.05 8.84 9.1 3.98 ± 1.00 1.23 7.34 41.6 1.57 2.63
0.75 0.1 4.42 8.8 3.84 ± 0.76 1.16 7.76 34.8 1.56 2.60
0.75 0.5 0.88 8.1 3.48 ± 0.76 1.20 7.28 31 1.56 2.53
0.75 1 0.44 6.8 3.40 ± 0.82 1.23 5.68 30.5 1.50 2.49
1 0.05 15.71 7.1 4.00 ± 0.94 1.19 7.52 44.8 1.63 2.55
1 0.1 7.85 9.5 4.02 ± 0.80 1.14 7.52 46.6 1.73 2.74
1 0.5 1.57 8.1 3.62 ± 0.74 1.17 6.70 39.8 1.58 2.48
1 1 0.79 7.7 3.73 ± 0.77 1.10 6.96 33.9 1.53 2.43
2.4 0.5 9 7.3 4.09 ± 0.81 1.15 7.44 47.3 1.84 2.69
2.4 1 4.5 9.3 3.98 ± 0.77 1.21 7.04 44.2 1.63 2.59
2.4 2 2.25 8.1 3.74 ± 0.64 1.15 6.62 38.6 1.51 2.46