Published in final edited form as: Phys Med Biol. 2020 Feb 28;65(5):055007. doi: 10.1088/1361-6560/ab3259

Table 3.

Relative permittivity (Mean ± SD) calculated by Full-form, Magnitude-based reconstruction and dielectric probe measurements.

Dielectric Probe Linear Birdcage Coil
Different salinities Average Permittivity at 900 MHz Full-form Relative Permittivity Magnitude-based Relative Permittivity
Tube 1 (0 g/L) 78.74 ± 0.14 86.93 ± 10.03 83.25 ± 09.91^
Tube 2 (4.7 g/L) 77.66 ± 0.01 85.00 ± 13.40 82.81 ± 13.03
Tube 3 (11.7 g/L) 76.13 ± 0.06 81.95 ± 09.12 77.49 ± 10.88^
Tube 4 (25.6 g/L) 73.41 ± 0.05 72.04 ± 13.03* 69.44 ± 12.83*

For EPT reconstructions, significance (*p<0.05) was found between tube 4 and all other samples using a one-way ANOVA with Tukey’s HSD post-hoc test.

The only other significant difference was found between tubes 1 and 3 at the ^p=0.05 level.