Table 3.

Mean (and standard deviation), maximum (Max), and minimum (Min) values of the indoor and outdoor airborne bacteria concentration in the tested environments (CFU/m3)

Locations C ± s Max Min
Indoor Outdoor Indoor Outdoor Indoor Outdoor
Classrooms Ground floor 162 ± 140 3019 ± 1725 1363 5924 52 524
1st floor 594 ± 405 7289 ± 4642 2411 17,352 52 1992
3rd floor 247 ± 157 8495 ± 8631 734 32,188 52 1887
Dorms Male 1956 ± 3407 6806 ± 6575 19,514 20,235 157 1101
Female 2847 ± 2554 8589 ± 8101 13,001 25,635 105 891
Dining hall Ground floor 513 ± 311 3853 ± 1697 1678 6448 105 1468

C is the mean concentration of all sampling positions, and s is the standard deviation. Twenty-nine sampling points were designated in the tested areas