. 2020 Feb 8;35(2):405–412. doi: 10.1007/s10877-020-00483-1

Table 5.

Receiver operating characteristic properties for prediction of re-intubation

AUROC (95% CI) Sensitivity (%) Specificity (%) PPV (%) NPV (%) Cutoff value
Respiratory rate (baseline) 0.73 (0.56–0.87)* 82 60 47 88  > 19
Respiratory rate (30 min) 0.75 (0.58–0.88)* 82 72 56 90  > 22
Respiratory rate ratio 0.64 (0.46–0.79) 91 48 44 92  > 0.95
RSBI (baseline) 0.71 (0.53–0.85)* 82 56 45 88  > 39.5
RSBI (30 min) 0.71 (0.54–0.85) 82 60 47 88  > 42.5
RSBI ratio 0.52 (0.35–0.69) 64 68 47 81  > 1.06
PPI (baseline) 0.54 (0.37–0.71) 36 92 67 74  > 4.4
PPI ratio (15 min) 0.63 (0.45–0.78) 82 44 39 84  ≤ 1.34
PPI ratio (30 min) 0.78 (0.61–0.9)* 91 72 59 95  ≤ 1.41

*Denotes statistical significance (P value < 0.05). AUROC Area under receiver operating characteristic curve, CI confidence interval, NPV negative predictive value, PPI peripheral perfusion index, PPV positive predictive value. RSBI rapid shallow breathing index. *denotes statistical significance