Skip to main content
. 2020 Apr 29;5(1):e000443. doi: 10.1136/tsaco-2020-000443

Table 2.

Accuracy and clinical outcomes for REBOA placement

All patients
(N=38)
Target zone 1
(n=30)
Target zone 3
(n=8)
P value
Accuracy of placement
 Target zone placement, n (%) 27 (71.1) 26 (86.7) 1 (12.5) <0.001
 Non-target zone placement, n (%) 11 (28.9) 4 (13.3) 7 (87.5)
Placement zone, n (%)
 Zone 1 29 (76.3) 26 (86.7) 3 (37.5) 0.008
 Zone 2 8 (21.1) 4 (13.3) 4 (50.0)
 Zone 3 1 (2.6) 0 (0) 1 (12.5)
Clinical outcomes
 REBOA-related complications, n (%) 2 (5.3) 2 (6.7) 0 (0) 1.000
 24-hour mortality, n (%) 19 (50.0) 17 (56.7) 2 (25.0) 0.232
 In-hospital mortality, n (%) 22 (57.9) 20 (66.7) 2 (25.0) 0.050

Categorical variables are presented as number (%).

REBOA, resuscitative endovascular balloon occlusion of the aorta.