Skip to main content
. 2020 Apr-Jun;12(2):116–123.

Table 5.

CCD experimental design and the responses. The data are the average of at least three experiments ± standard deviation

Run X1 X2 X3 Extract D.W. (mg/l) Cell Death HepG2 (%) Cell Death A549 (%) Response A549 (%)
1 −1 −1 −1 66.7 11.5±4.9 15.6±3.5 5.8
2 +1 −1 −1 93.4 96.5±4.8 98.3±1.7 51.3
3 −1 +1 −1 70.0 99.3±4.8 97.4±2.5 38.2
4 +1 +1 −1 93.4 95.3±5.6 98.5±1.3 48.8
5 −1 −1 +1 106.7 46.9±2.0 40.2±4.5 23.9
6 +1 −1 +1 158.9 28.4±4.4 23.1±4.8 20.5
7 −1 +1 +1 76.7 56.5±3.9 50.8±3.4 21.8
8 +1 +1 +1 178.8 36.1±0.2 32.8±1.5 32.8
9 −1.73 0 0 55.6 32.6±3.9 27.5±2.0 17.3
10 +1.73 0 0 122.2 77.26±0.9 64.2±1.1 43.9
11 0 −1.73 0 91.2 38.5±2.0 37.4±4.8 19.0
12 0 +1.73 0 126.7 80.03±2.8 70.2±0.2 49.7
13 0 0 −1.73 83.3 51.6±5.3 49.9±14.2 23.0
14 0 0 +1.73 171.2 19.02±0.6 16.2±7.3 15.5
15 0 0 0 126.7 97.7±3.8 99.2±0.1 70.3
16 0 0 0 130.0 98.9±1.7 95.4±4.2 69.4
17 0 0 0 126.7 95.0±1.4 97.3±2.6 68.9
18 0 0 0 124.5 99.9±5.4 97.4±3.3 67.8
19 0 0 0 135.6 97.3±0.9 97.0±2.0 73.6
20 0 0 0 144.4 93.8±4.5 97.5±3.0 78.7

CCD: Central composite design, D.W.: Dry weight.