Table 1.
The conditions of GED/MS experiment.
| nozzle-to-plate distance, mm | 338 | 598 |
| fast electron beam, μA | 1.47 | 0.64 |
| temperature of effusion cell, K | 431(5) | 401(5) |
| accelerating voltage, kV | 79.2 | 79.5 |
| (electron wavelength), Ǻ | 0.04200(3) | 0.04192(4) |
| ionization voltage, V | 50(1) | 50(1) |
| exposure time, s | 130–140 | 50–60 |
| residual gas pressure, Torr | 1.0⋅10−6 | 2.5·10−6 |
| s-values range, Å−1a | 2.5–23.9 | 1.3–16.1 |
s = (4π/λ)sinθ/2, λ is electron wavelength and θ is scattering angle.