Skip to main content
. 2020 Apr 2;11(4):374. doi: 10.3390/mi11040374

Table 2.

Flow properties associated to the images of Figure 15. The reported percentage change indicates how much the properties vary inside the group of Ni = 20 average images.

Image Δt (µs) pm (Pa) Δp (Pa) m˙CV (kg/s) Ma (–) Kn (–)
Figure 15a 20 6904 ± 1.2% 371 ± 0.3% 5.4 × 10−6 ± 1.5% 0.032 ± 0.27% 7.3 × 10−4 ± 1.2%
Figure 15b 30 6620 ± 1.2% 367 ± 0.31% 5.2 × 10−6 ± 1.5% 0.031 ± 0.29% 7.3 × 10−4 ± 1.2%
Figure 15c 40 6337 ± 1.2% 362.8 ± 0.31% 4.9 × 10−6 ± 1.5% 0.031 ± 0.3% 8 × 10−4 ± 1.2%
Figure 15d 50 6071 ± 1.2% 358.6 ± 0.31% 4.6 × 10−6 ± 1.5% 0.031 ± 0.31% 8.3 × 10−4 ± 1.2%