Skip to main content
. 2020 Apr 4;118(10):2596–2611. doi: 10.1016/j.bpj.2020.03.018

Table 2.

AP and CaTr biomarkers Simulated by the Paci2020 hiPSC-CM Model at 37°C

Biomarker (Reference) Experimental Value (Mean ± SD) Simulated Value
APA (mV) (50) 104 ± 6 102
MDP (mV) (50) −75.6 ± 6.6 −74.9
AP CL (ms) (50) 1700 ± 548 1712
dV/dtmax (V/s) (50) 27.8 ± 26.3 20.5
APD10 (ms) (50) 74.1 ± 26.3 87.0
APD30 (ms) (50) 180 ± 59 224
APD90 (ms) (50) 415 ± 119 390
AP Tri (−) (50) 2.5 ± 1.1 2.8
CaTr DURATION (ms) (16) 805 ± 188 691
CaTr tRise10, 50 (ms) (16) 82.9 ± 50.5 54.9
CaTr tRise10, 90 (ms) (16) 167 ± 70 118
CaTr tRise10, peak (ms) (16) 270 ± 108 184
CaTr tDecay90, 10 (ms) (16) 410 ± 100 341
CaTr CL (ms) (16) 1654 ± 630 1712

AP and CaTr biomarkers are from (16). Both AP and CaTr biomarkers were recorded at 37°C. AP biomarkers (patch-clamp): APA, AP amplitude; MDP, maximal diastolic potential; CL, cycle length; dV/dtmax, maximal upstroke velocity; APD10, APD30, APD90, AP duration at 10, 30, and 90% of repolarization; AP triangulation (AP Tri) computed as the ratio between APD30–APD40 and APD70–APD80; CaTr DURATION, CaTr rise time from 10 to 50% (CaTr tRise10, 50), 90% (CaTr tRise10, 90), and to CaTr peak (CaTr tRise10, peak), decay time from 90 to 10% (CaTr tDecay90, 10), and CaTr rate (CaTr CL).