. 2020 May 6;36(4):247–256. doi: 10.1089/jop.2019.0081

Table 5.

Eye Tissue Distributions of IgG After 20 Min Anodal Iontophoresis at Two Different Current Densities: 1.86 and 3.6 mA/cm2

Tissue (n = 6) 3.6 mA/cm2
1.86 mA/cm2
Amount of IgG (μg) Conc. [IgG (μg)/g tissue] Amount of IgG (μg) Conc. [IgG (μg)/g tissue]
Cornea 112.5 ± 36.6 1470.2 ± 478.4 46.1 ± 12.1 602.1 ± 158.4
Aqueous humor 1.8 ± 0.2 6.3 ± 0.8 1.9 ± 1.1 6.9 ± 3.9
Lens 1.9 ± 1.4 4.6 ± 3.5 0.8 ± 0.6 2.1 ± 1.6
Vitreous 7.2 ± 2.9 4.9 ± 2.0 2.6 ± 1.3 1.8 ± 0.9
Retina/choroid 42.1 ± 38.8 268.6 ± 247.5 7.5 ± 7.4 48.1 ± 47.0
Sclera 186.9 ± 75.4 539.1 ± 217.5 131.4 ± 37.3 378.9 ± 107.5
Conjunctiva 374.6 ± 113.9 545.3 ± 165.8 247.6 ± 42.5 360.4 ± 61.9
Total 727.1 ± 37.7   438.0 ± 63.3  

The higher current density (3.6 mA/cm2), the applicator was replaced at 10 min to maintain neutral pH in the applicator.

Conc., concentration.