Skip to main content
. 2020 Mar 25;10(4):179. doi: 10.3390/diagnostics10040179

Figure 3.

Figure 3

Time-course changes of tear meniscus height, tear meniscus area, and strip meniscometry value before surgery, during the silicone tube intubation, after removing the silicone tube. (a) Tear meniscus height decreased significantly after removing the silicone tube, compared to before the surgery. (b) The tear meniscus area decreased significantly after removing the silicone tube, compared to before the surgery. (c) The SMTube value decreased significantly after removing the silicone tube compared to before the surgery and during the silicone tube intubation. * p < 0.05.