Skip to main content
. 2020 May 18;20:51. doi: 10.1186/s12880-020-00446-7

Table 3.

Accuracies of diagnostic methods

Parameters Computed tomographic colonography Colonoscopy
For polyp ≥10 mm ø 0.926 0.920
For polyps < 10 mm ø but suspicious 0.959 0.837

Lesion ulceration, extramural invasion, and/ or lesion shouldering was considered as suspicious polyp

ø: Diameter