Skip to main content
. 2020 Spring;72(2):149–157. doi: 10.3138/ptc-2018-0105

Table 5.

Feasibility of Using pUSI and the Acoustic Standoff Pad to Measure the mCSA (N = 26)

Feasibility pUSI
Acoustic standoff pad
RF BB LG* RF BB LG*
Image acquisition
 Time, min, mean (SD) 3 (2) 5 (3) 3 (2) 3 (2) 4 (2) 4 (3)
 Ease of visualizing muscle borders 5 (2–5) 4 (2–5) 5 (3–5) 4 (2–5) 4 (2–5) 4 (2–5)
 Ease of obtaining images 5 (3–5) 4 (2–5) 5 (3–5) 5 (3–5) 4 (2–5) 4 (2–5)
Image analysis
 Time, min, mean (SD) 4 (2) 5 (2) 4 (2) 4 (2) 5 (2) 4 (2)
 Ease of tracing muscle borders 4 (3–5) 4 (2–5) 4 (2–5) 4 (2–5) 3 (2–5) 4 (1–5)

Note: Unless otherwise indicated, results are presented as median (range, min–max).

*

n = 25.

pUSI = panoramic ultrasound imaging; mCSA = muscle cross-sectional area; RF = rectus femoris; BB = biceps brachii; LG = lateral gastrocnemius.