Skip to main content
. 2020 May 3;11(3):155–167. doi: 10.14740/cr1011

Table 4. Aortic Valve Complex Calcification.

RV pacing-dependent at 30 days (n = 8) Non-RV pacing-dependent at 30 days (n = 16) P-value
Mean attenuation 336.6 ± 87.6 353.8 ± 120.2 0.72
HU cutoff 353.8 ± 70.7 539.8 ± 66.9 0.62
Total calcium volume 783.5 ± 622.1 420.3 ± 264.2 0.055
LVOT calcium volume 673.7 ± 202.8 697.6 ± 34.7 0.18
Annulus calcium volume 117.9 ± 120.6 92.9 ± 50.4 0.48
RCC leaflet calcium volume 119.7 ± 121.5 107.2 ± 119.9 0.81
NCC leaflet calcium volume 342.0 ± 290.8 113.6 ± 63.2 0.006
LCC leaflet calcium volume 139.9 ± 132.7 91.4 ± 87.0 0.29
Total leaflet calcium volume 601.6 ± 504.9 312.2 ± 248.8 0.07

The P-values shown are derived from two-tailed unpaired Student’s t-test for continuous variables. Patients who were non-RV pacing-dependent at 30 days and patients who were RV pacing-dependent at 30 days patients were separately compared. Continuous variables are reported as the mean plus or minus the standard deviation. HU: Hounsfield Units; LVOT: left ventricular outflow tract; RCC: right coronary cusp; NCC: non-coronary cusp; LCC: left coronary cusp; RV: right ventricular.