E’ value of nanocomposites of PCL at different temperature ranges. [37], Reproduced with permission from Fukushima K, Mater. Sci. Eng. C; published by Elsevier, 2009.

Sample E’ at −125 °C (MPa) E’ at −75 °C (MPa) E’ at −25 °C (MPa) E’ at 30 °C (MPa)
PCL 4715 3451 891 503
PCL + 5% CLO30b 5071 3882 1312 762
PCL + 5% NAN804 4864 3663 1075 599
PCL + 5% SEPS9 4767 3602 1207 751