Table 2. Tissue and fluid properties, pulse sequences and sequence parameters, and image features.

Tissue and fluid properties Pulse sequences and sequence parameters Image features
ρm Spin echo (TR, TE) S, signal
T1
T2
Inversion recovery (TR, TI, TE…) Cab, absolute contrast, ∆S
Cfr, fractional contrast, ΔSS
D*, apparent diffusion coefficient Pulsed gradient spin echo (TR, TE, b …) σ = standard deviation of noise
χ, susceptibility Spoiled gradient echo (TR, TE, α) SNR, signal-to-noise ratio
δ, chemical shift CNR, contrast-to-noise ratio CNR=Cabσ,Cfrσ
T2/T1 Balanced steady state free precession (TR, TE, α….)
Ultrashort T2 Ultrashort TE (TR, TE, α) θ, phase
Flow PGSE (TR, TE, δ, Δ) Phase to noise ratio (PNR=θσ)
Gadolinium concentration, c Other phase contrast ∆θ
phase contrast to noise ratio (PCNR)=Δθσ

The tissue and fluid properties (left column) are linked to image signal or phase and contrast (right column) by pulse sequence TP-filters derived from pulse sequence equations (middle column).