Table 3.
Site of samples collection | Sample code | Heavy metals analyzed (ppb or µg/L) | |||||
---|---|---|---|---|---|---|---|
Hg (0.1)a | Pb (0.1) | Cr (0.5) | Cd (0.05) | Tl (0.01) | Ni (0.2) | ||
Waste water: | |||||||
Tetrapak | A2 | <0.1 | 9.5 | 0.7 | 0.09 | <0.01 | 1.7 |
Chief’s Camp | B3a | <0.1 | 29.5 | 2.9 | 0.08 | 0.04 | 2.1 |
Chief’s Camp | B3b | <0.1 | 28.2 | 2.7 | 0.11 | 0.09 | 2.6 |
Railways Lower | C2 | <0.1 | 8.3 | 9.8 | 0.17 | 0.08 | 21.1 |
Railways Upper | D2 | <0.1 | 6.9 | 2.1 | 0.09 | 0.08 | 6.1 |
Davis & Shirtliff | E2 | <0.1 | 24.2 | 1.9 | 0.13 | 0.05 | 2.6 |
Kartasi | F3 | <0.1 | 17.3 | 1.4 | 0.08 | 0.03 | 6.5 |
Sinai | G3 | <0.1 | 0.4 | 50.7 | <0.05 | 0.03 | <0.2 |
Donholm | H2 | <0.1 | 13.5 | 0.9 | <0.05 | 0.02 | 1.7 |
Mean concentration ± SE (ppb) | <0.1 ± 0.00 | 15.31 ± 3.39 | 8.12 ± 5.40 | 0.09 ± 0.01 | 0.05 ± 0.009 | 4.96 ± 2.13 | |
Mean concentration (ppm or mg/l) | <0.0001 | 0.01531 | 0.00812 | 0.00009 | 0.00005 | 0.00496 | |
Tap water (control) - ppb: | |||||||
Roysambu (House)b | I3 | < 0.1 | 1.6 | 0.6 | <0.05 | <0.01 | <0.2 |
aThe value in bracket shows the method detection limit (MDL) measured in ppb. bTap water samples were acidified with HNO3 before metal analysis.