Comparison of the diagnostic sensitivity for N, L, and NLR

  Influenza virus infection (N = 107) Healthy control (N = 100) Reference range Sensitivity P value
N (109/L) 6.247 ± 5.700 3.226 ± 0.913 1.8‐6.3 37.40% <.001***
L (109/L) 1.167 ± 1.341 2.111 ± 0.429 1.1‐3.2 60.75% <.001***
NLR 8.877 ± 9.855 1.595 ± 0.507 0.581‐2.61 70.09% <.001***

The reference range of NLR was the 95% confidence interval of NLR in the control group, P < .01. Student's t test for independent samples was used to compare continuous variables.

*