Average concentrations of chromium (Cr), mercury (Hg), nickel (Ni), and lead (Pb) in house dust and airborne dust stratified by village.

BanKok (84) BanKlang (18) p
Range Mean ± SD Median IQR Range Mean ± SD Median IQR
House dust (mg/kg)
Cr ND–6.33 1.51 ± 1.24 1.56 0.06–1.11 0.37 ± 0.30 0.40 0.000
Hg ND–1.04 0.07 ± 0.17 0.08 ND–0.10 0.02 ± 0.03 0.04 0.328
Ni ND–12.00 1.32 ± 1.65 1.11 ND–1.55 0.45 ± 0.42 0.51 0.000
Pb ND–79.27 5.86 ± 10.49 6.49 ND–5.43 1.24 ± 1.66 2.09 0.000
Air dust (µg/m3)
Cr ND–0.14 0.03 ± 0.04 0.05 ND–0.06 0.01 ± 0.02 0.01 0.001
Hg ND–0.26 0.14 ± 0.06 0.09 ND–0.12 0.05 ± 0.03 0.02 0.000
Ni ND–0.13 0.04 ± 0.04 0.06 ND ND ND 0.000
Pb ND–1.66 0.09 ± 0.19 1.24 ND–0.12 0.01 ± 0.03 ND 0.000

IQR, interquartile range; ND, not detected; SD, standard deviation. Mann-Whitney U test significance set at α = 0.05.