Table 3.
Assessment | Sequence | Comment |
---|---|---|
Function | CINE | Use acceleration (e.g. compressed sensing), limited number of acquisitions, acquisition after contrast injection/before LGE |
Oedema | T1/T2 Mapping/T2 STIR | Mapping preferred to T2-STIR because of image quality, use limited representative SA slices for screening |
Scar | 3D-PSIR (SA) | LGE imaging after 6 min post contrast administration; adjust contrast media protocol |
Thoracic | T2 | One breath-hold sequences for lung pathology |
SA : Short Axis