Table 1.

Photoacoustic NDIR demonstrations. Both the concentration range as well as the limit of detection are stated for ambient pressures of 1 bar. The values are stated either in part-per-million (ppm), parts-per-billion (ppb), or percent (%), whichever is most appropriate.

Light Source Sound Transducer Target Gas/Measurement Range Concentration Range and Limit of Detection (LOD) Citations
Thermal source Microphone Carbon dioxide (CO2) 0 %–100 %
LOD not stated
[57]
0 ppm–2500 ppm
8.69 ppm
[58]
Carbon Monoxide (CO) 0 ppm–70 ppm
LOD not stated
[59]
0 ppm–2500 ppm
8.83 ppm
[58]
Methane (CH4) 0 %–100 %
LOD not stated
[57]
0 ppm–2500 ppm
10.29 ppm
[58]
LED Microphone Carbon dioxide (CO2) 0 ppm–5000 ppm
100 ppm
[52]
0 ppm–7000 ppm
345 ppm
[50]
0 ppm–7000 ppm
LOD not stated
[60]
0 %–100 %
2,053 ppm
[56]
Methane (CH4) 0 %–100 %
LOD not stated
[61]
0 %–100 %
5024 ppm
[56]
0 %–6 %
2510 ppm
[51]
QTF Carbon dioxide (CO2) 0 %–100 %
LOD not stated
[62]
Methane (CH4) 0 %–100 %
LOD not stated
[62]
Laser Microphone Methane (CH4) 0 ppm–1100 ppm
LOD not stated
[63]
Cantilever Ethylene (C2H4) 0 ppm–1000 ppm
10 ppb
[64]