Table 3.

Mean fracture load (N), fracture stress (MPa) and crack size (c in μm) values for the experimental groups, followed by standard deviation (SD) and coefficient of variation (CV).

Fracture Load (N) c (μm) Fracture Stress (MPa)
Groups Mean (SD) CV (%) Mean (SD) Mean (SD)
YZ16 4526 (406)a 9 25 (5)b 1100 (115)a
YZ16-CM 3992 (653)b 16 31 (4)a 940 (49)b
IZ16 2310 (134)c 6 38 (6)a 470 (41)c
IZ16-MC 2220 (244)c 11 34 (5)a 500 (38)c
AL16 1973 (238)c 12 38 (5)a 460 (27)c
AL16-MC 2021 (253)c 13 37 (6)a 480 (37)c
YZ9 2205 (186)c 8 32 (6)ab 940 (82)b
*

Values followed by the same letter in the column are statistically similar (p>0.05).