Table 2. Tissue composition, blood oxygenation, and scatter parameters for all the subjects at the three source detector separations for location at 4 cm to the left of the navel. a .

Subject # ρ cm Hb µM HbO2 µM THb µM StO2 % Lipid mg/cm3 water mg/cm3 collagen mg/cm3 bkg cm-1 A cm-1 b
1 1 0.83 10.83 11.66 93 955 216 90 0.001 14.5 1.26
2 0.20 15.89 16.09 99 969 185 88 0.020 18.7 0.38
3 0.13 14.40 14.53 99 884 141 75 0.019 13.7 0.44

2 1 2.86 5.29 8.15 65 664 221 0 0.010 12.0 1.21
2 0.09 18.60 18.68 100 1164 154 54 0.020 15.5 0.03
3 0.07 16.14 16.21 100 1188 43 71 0.015 12.3 0.52

3 1 2.89 4.90 7.79 63 605 197 0 0.010 13.6 1.08
2 0.00 17.08 17.08 100 930 136 22 0.021 14.9 0.00
3 0.23 15.56 15.79 99 977 85 30 0.015 12.2 0.43

4 1 0.33 33.30 33.64 99 994 281 140 0.036 22.2 1.56
2 0.08 42.52 42.61 100 483 535 143 0.073 23.2 0.00
3 0.05 50.25 50.30 100 1247 291 205 0.084 18.9 0.24

5 1 2.84 5.52 8.36 66 690 236 0 0.010 15.0 0.83
2 0.05 19.25 19.30 100 994 108 33 0.024 17.3 0.00
3 0.01 18.11 18.12 100 1046 57 43 0.019 13.1 0.29

6 1 2.90 4.72 7.63 62 574 185 0 0.010 12.4 1.42
2 0.33 12.21 12.54 97 950 132 35 0.018 16.0 0.29
3 2.66 6.62 9.28 71 720 286 0 0.011 11.8 0.67

7 1 2.90 4.69 7.59 62 568 182 0 0.010 10.3 1.41
2 0.07 9.96 10.03 99 1171 116 86 0.006 16.7 0.70
3 0.15 7.89 8.03 98 1085 106 77 0.003 12.9 0.74

8 1 2.02 32.19 34.21 94 811 10 56 0.031 15.7 1.07
2 0.01 43.62 43.63 100 824 368 141 0.075 25.7 0.15
3 0.74 40.71 41.46 98 899 202 133 0.060 15.6 0.18

9 1 0.27 15.89 16.16 98 1028 145 132 0.002 18.0 1.48
2 0.12 25.95 26.07 100 888 312 131 0.062 26.7 0.43
3 0.00 30.24 30.25 100 997 203 143 0.049 16.0 0.36

10 1 2.90 4.76 7.66 62 583 186 0 0.010 18.6 1.37
2 0.03 10.81 10.84 100 984 101 57 0.015 19.3 0.33
3 0.02 8.51 8.53 100 985 75 59 0.008 13.7 0.51
a