Skip to main content
. Author manuscript; available in PMC: 2021 Apr 7.
Published in final edited form as: Lab Chip. 2020 Feb 27;20(7):1238–1248. doi: 10.1039/c9lc01171d

Table 1.

Summary of nanoparticle synthesis results (from DLS) across various flow rates using the acoustofluidic mixer

Flow rate (μL min−1) Acoustics OFF
Acoustics ON
Zavg (nm) PDI Zavg (nm) PDI
20 177.64 0.076 93.76 0.163
400 110.46 0.052 65.76 0.070
2000   75.56 0.095 64.51 0.062