Posterior Fusion for the Subaxial Cervical Spine: A Review of the Major Techniques

Christopher M Mikhail 1,✉, James E Dowdell III 1, Andrew C Hecht 1
PMCID: PMC7253542  PMID: 32508546

Abstract

Posterior fusion is a powerful tool to address pathology of the cervical spine, but the decision to fuse at any level should be made with great care. Various methods and constructs for posterior cervical fusion exist, all of which aim to restore the posterior tension band’s ability to resist flexion forces. We identified articles regarding posterior fusion of the subaxial cervical spine in MEDLINE, Google Scholar, and PubMed. This article is a narrative review of earlier and current concepts regarding the posterior fusion of the subaxial cervical spine, including wiring, translaminar screws, lateral mass screws, and pedicle screws, weighing the strengths and weakness of the different modalities that the surgeon should bear in mind in creating operative plans individualized to patient pathology.

Electronic supplementary material

The online version of this article (10.1007/s11420-019-09722-x) contains supplementary material, which is available to authorized users.

Keywords: cervical spine, spinal fusion, cervical myelopathy, surgical techniques

Introduction

In the case of spinal instability, fusion is always a consideration. When a decision about whether to fuse—at any level—must be made, caution should be exercised. Unfortunately, spinal instability has many definitions, the foremost of which, as described by White and Panjabi, is a loss of the ability of the spine to tolerate pain, structural deformity, or neurological damage under physiological loads [51]. Instability may also be defined as injury to two or more of the three columns of the subaxial cervical spine in the three-column model of spinal trauma [11]. The extent of spinal instability can be further characterized using these definitions in combination with clinical examination and imaging via radiographs, computed tomographic (CT) scanning, and magnetic resonance imaging (MRI) [37, 47].

There are a variety of methods and constructs for posterior cervical fusion, each of which has benefits and drawbacks. The benefit shared by all posterior fusion constructs is the restoration of the posterior tension band in order to allow it to resist flexion forces. Historically, posterior cervical fusion was performed by onlaying autogenous bone graft to posterior elements. Although successful, this technique was typically followed by extended and poorly tolerated bed rest and orthosis use. The first type of posterior cervical fusion to involve hardware was described in the 1890s by Hadra, who used a wire to fix the posterior elements of the spine [20]. Since then, many new modalities have been introduced, including lateral mass screws, translaminar screws, and pedicle screws with malleable rods. These constructs all provide immediate stability, allowing earlier mobilization and rehabilitation while the patient awaits bony fusion.

Posterior fusion of the subaxial cervical spine is a powerful tool in the treatment of instability caused by trauma, tumor resection, rheumatoid arthritis, ankylosing spondylitis, post-laminectomy kyphosis, infection management, and revision cervical fusion. The purpose of this article is to provide a narrative review of current concepts in posterior cervical fusion, with a focus on indications, operative techniques, and outcomes. We conducted searches in MEDLINE, Google Scholar, and PubMed to identify articles on posterior fusion of the subaxial cervical spine and describe the major techniques, their history, and their current uses in clinical practice.

Posterior Cervical Noninstrumented Fusion

The earliest form of posterior fusion of the subaxial cervical spine involved laying autologous bone graft along the posterior spinal elements, allowing for the cervical levels to fuse over time [32]. This procedure was often followed by long periods of immobilization with rigid orthosis and delayed rehabilitation to allow for bony fusion to occur. Additionally, the technique was not useful in cases of unstable spinal injuries because it does not immediately stabilize the spine. Although this technique is used by itself rarely today, it is sometimes used in conjunction with instrumented fusions.

Bony fusion is only achieved with proper technique, which requires adequate preparation of the fusion bed. The surgeon must remove all soft tissue and periosteum to adequately expose the posterior bony elements and facet joints. The cartilage must be removed from all facet joints by using curettes, osteotomes, or high-speed burr. The spinal elements must then be decorticated with the use of a high-speed burr or series of curettes until bleeding cancellous bone is seen. Once the fusion bed has been adequately prepared, the bone graft may be laid onto the exposed elements. Autograft is ideal because it is osteoinductive, conductive, and integrative [39]. If the surgeon is unable to obtain adequate autograft, cancellous bone graft may be added to augment the fusion. Additionally, cortical bone may be used for structural support in areas with large bony gaps [32].

Posterior Cervical Wiring

Because onlay techniques were found to be unreliable in conferring adequate stability and involved arduous rehabilitation protocols, new techniques were developed. Wiring of the posterior cervical spine is relatively simple to perform. It requires that the posterior spinal elements be intact in order to create a tension band posteriorly and improve resistance to flexion forces in the neck [32]. Wiring can be performed with monofilament wire, Drummond buttons, or braided cables. The wire is placed with cortical bone graft and tightened using a crimping device. Although wiring is rarely used today, it is a safe and cost-effective technique for posterior cervical fusion in cases of traumatic instability [33, 50].

Interspinous wiring was originally described, in 1891, as a method for stabilizing the spine in Pott’s disease [20]; it was later used for traumatic instability of the cervical spine. The first technical description of interspinous wiring was presented by Rogers [44]. It begins with drilling a transverse hole in both the superior and inferior spinous process and passing a wire from superior to inferior in a figure-eight fashion and augmented with cortical bone, as shown in Fig. 1 [16]. This technique was found to be successful in achieving arthrodesis in all 11 patients described by Rogers. This technique was later modified by many, including Abdu and Bohlman [1], Whitehill et al. [52], and Benzel and Kesterson [6].

Fig. 1.

Fig. 1

Stepwise illustration of the Rogers technique for posterior cervical wiring. Courtesy of Ghori et al. [16].

Abdu and Bohlman proposed a triple wiring technique that conferred greater biomechanical stability [1]. The first wire was passed in a fashion similar to that described by Rogers and then augmented with two more wires: the second wire is passed through the superior hole in the spinous process and looped around the superior spinous process; the third wire is passed in the inferior hole and looped around the inferior spinous process. These two wires are then passed through holes in cortical strut bone autograft and tightened onto the decorticated spinous processes.

Callahan et al. proposed facet wiring as a useful alternative to posterior fusion when spinous processes and laminae are deficient [8]. This procedure begins with thorough exposure of the lateral masses at the selected levels. The facet joints are then opened and decorticated. Holes are drilled perpendicular to the inferior articular processes, and a wire is placed at the highest level and passed toward inferior levels. The wires are then wrapped around cortical strut bone grafts, securing them to the exposed decorticated facet joints (Fig. 2) [16]. In cases in which cortical strut autograft is not obtained, one may place contoured Steinmann pins, Luque rectangles, or rods to allow for rigid fixation [15, 38].

Fig. 2.

Fig. 2

The Bohlman technique for posterior cervical wiring. Courtesy of Ghori et al. [16].

Cahill et al. later proposed a combination of the two wiring techniques for cases in which there is traumatic instability of the posterior elements [7]. A similar exposure is performed, and the wire may be passed in an oblique orientation from the facet to the inferior aspect of the caudal spinous process on both sides. The elements are then decorticated, and autologous bone graft is placed in an onlay fashion. In Cahill et al.’s report, the technique achieved 100% success in 18 patients with facet fracture dislocations.

Major complications with this technique are rare [50]. The most common are wire pullout, avulsion fractures, and hyperlordosis caused by overtensioning of the wire [32]. Additionally, the wire may compress underlying neural structures, causing injury to the cord or exiting spinal nerves. In patients with poor bone quality or the capacity to heal, the wire construct may pull out and fail. These complications may be prevented with thorough pre-operative planning and avoiding the use of the technique alone in patients with anterior or middle column instability. In addition, the wire should never be kinked, and each hole should be made with a single pass in a transverse fashion, in order to avoid a stress riser or pullout of the wire [16].

Translaminar Screws

Translaminar screws are more commonly used in the atlantoaxial and thoracolumbar spine where the lamina is more capacious [18, 42]. They are particularly useful as a salvage option when the lateral mass is deficient or lateral mass screw placement has failed. Given the small size of the lamina in the subaxial cervical spine, C3–C6 screws are associated with high failure rates and are rarely used [3, 49]. However, two recent studies suggest that they can be successfully placed at the C7 level: unilateral placement of a 3.5-mm screw at C7 was successful 100% of the time, and bilateral placement was successful 90% of the time. The use of 4.0-mm screw at C7 has slightly lower success rates, at 91.7% and 66.8%, respectively. CT imaging is crucial in calculating screw size, length, and trajectory to ensure optimal positioning. The length of the screw is ideally measured from the contralateral spinolaminar junction to the ipsilateral lamina–lateral mass junction. The entry point is then drilled with a high-speed burr at the contralateral spinolaminar junction. The trajectory is then hand drilled and tapped, and checked with a depth gauge. Once the depth gauge confirms the length of screw and no violation of the cortex, a 3.5- or 4.0-mm screw can be placed.

The use of translaminar screws in the subaxial cervical spine is quite limited and only appropriate in specific cases. As with other posterior fixation methods, translaminar screws are only possible when the posterior elements are intact. At the C7 level, the most common misplacement of screws is dorsal cortex breach with no injury to vital surrounding structures [23, 24]. Misplacement through the medial or anterior cortex puts the spinal cord and thecal sac at risk. This risk is minimized with adequate pre-operative planning with measurement on CT scan. Intra-operatively, the depth gauge should be used to assess for violation of the medial and anterior cortex before screw placement. Additionally, neuromonitoring screw stimulation may be used to further confirm the safety of the underlying neural structures. As with all hardware placement in the spine, screw loosing and failure may also occur [23, 24, 26].

Posterior Cervical Lateral Mass Screws

The lateral mass lies anterolateral to the lamina and consists of the superior and inferior articular facets. The bone stock here is large and allows strong posterior fixation in patients with instability of the subaxial cervical spine, which leads to highly successful fusion rates. Lateral mass screws have proven to have superior stability, as compared with translaminar screws and wiring [5, 13, 17]. Lateral mass screws may be used in cases of traumatic instability, infection, malignancy, degenerative instability, and failed anterior fusions. Lateral mass screw fixation has therefore become the most commonly used technique for achieving posterior fixation of the subaxial cervical spine since its introduction in 1964 by Roy-Camille [45].

Given its early success, the method was popularized by Nazarian and Louis [40] and Magerl et al. [27], then later by Anderson et al. [5] and An et al. [4]. Although many alternative techniques have been proposed, they differ only in start site and trajectory of the screw. The Roy-Camille method begins at the midpoint of the lateral mass, from medial to lateral and superior to inferior. An entry hole is burred with a 2-mm drill bit, angled perpendicular to the posterior wall and 10° laterally. The hole is then tapped with a 3.5-mm tap and probed to confirm bony walls on all sides. Depth is then measured, and the appropriate length screw is placed. The benefit of this technique is that it carries a lower risk of nerve root injury, but it also takes a shorter screw length and confers a greater chance of facet joint penetration.

Each of these techniques has its benefits and pitfalls. A cadaveric study performed by Heller et al. compared the Magerl and Roy-Camille techniques and found that the trajectory used in the Magerl technique allows for longer screws and confers a lower risk of facet penetration [21]. Another anatomic study, which compared the Magerl, Anderson, and An techniques, found the lowest nerve penetration with the trajectory proposed by An [53]. The Nazarian and Louis technique describes the simplest and most reproducible method, whereas An’s technique is more difficult to reproduce but employs a longer screw and carries the lowest risk of nerve violation. These techniques are summarized in Table 1.

Table 1.

Techniques for lateral mass screw fixation

Name of technique Entry point Lateral angulation Sagittal inclination
Roy-Camille technique Midpoint 10° from sagittal plane 90° perpendicular to the surface
Nazarian and Louis technique Intersection of a vertical line 5 mm medial to the lateral aspect of the facet, and a horizontal line 3 mm below the underlying facet Straight ahead 90° perpendicular to the surface
Magerl technique 1 mm medial and cranial to the midpoint 20°–30° from sagittal plane 30°–40° cephalad, parallel to the adjacent facet joint
Anderson technique 1 mm medial to the midpoint 10° from the sagittal plane 30°–40° cephalad, parallel to the adjacent facet joint
An technique 1 mm medial to the midpoint 30° from the sagittal plane 15° cephalad

Regardless of the placement technique used, lateral mass screws were often placed through plates, thereby limiting their ability to accommodate abnormal spinal anatomy, and had the potential of causing iatrogenic foraminal stenosis [22]. To expand the utility of these constructs and minimize associated iatrogenic radiculopathy, clamps and malleable rods have replaced the plates. This provides the benefit of precise screw placement and the ability to apply compressive, distractive, or lateral rotary forces for correction of deformity [25].

Fortunately, complications associated with lateral mass screws are exceedingly rare and often avoidable. Care should be taken to ensure proper placement. This can be accomplished through intra-operative fluoroscopy to ensure ideal starting point and trajectory. Lateral mass screws put the spinal cord, vertebral artery, and exiting spinal nerves at risk when aimed anteromedially, so one should always be very careful to aim laterally. Additionally, one can injure the facet joints, which may result in junctional level spondylosis and pain. Rarely, the screws may loosen and pull out, which can result in failure of fusion or migration of hardware. Although bicortical purchase increases the pullout strength of a screw, if there is concern about inappropriate trajectory of the screw, the surgeon should sacrifice the bicortical fixation for the safer, unicortical placement. If nerve injury is suspected, MRI should be performed. When the articular masses are deficient, lateral mass screws should be avoided, in order to avoid complications. Such deficiency can be due to trauma or occur after a resection and in cases in which posterior elements are osteoporotic or comminuted. Additionally, lateral mass screws have not been as effective in cases with severe instability and may require augmentation with additional anterior fusion.

Posterior Cervical Pedicle Screws

Although pedicle screws are the gold standard in posterior fixation of the lumbar and thoracic spine, they are not as commonly used in the cervical spine. Their small diameter and aggressive medial angulation lead to high rates of pedicle perforation during screw placement. This poses a risk of serious adverse events, such as vertebral artery perforation through the lateral wall and spinal cord injury through the medial wall. With such high medial angulation at more cranial levels, one must expose far laterally, which is sometimes not possible in patients with an anomalous vertebral artery at the C2 level [36] or in those with a narrow C1 posterior arch [56].

The benefit of pedicle screws lies in their being a good alternative when lateral mass screws are not a viable option, such as when comminution or deficient posterior elements preclude their placement.

Pedicle screws have been proven to have greater biomechanical strength than lateral mass screws, with two to three times the pullout strength [28, 31]. This makes them the preferred screws when there is severe instability that would not be stabilized with posterior lateral mass screw fixation alone. In fact, pedicle screws rarely fail because of pullout; if they fail, it is typically because of pedicle fracture, unlike lateral mass screws that pull out under cyclic load.

Pedicle screw fixation has been highly successful at achieving stable fusion in difficult cases that may compromise the lateral masses, including spondyloarthropathies, inflammatory arthritis, malignancy resection, and trauma. It has also been successful in correcting kyphotic deformity and providing stable occipitocervical and cervicothoracic fusion constructs.

Pedicle screw placement is difficult and should be performed with caution. In addition to using intra-operative fluoroscopy, one should obtain advanced imaging that clearly defines the pedicle lateral-to-medial trajectory at each level. When originally introduced by Abumi and Kaneda in 1994, the starting point was said to be 1 mm lateral to the center of the articular mass and at the cranial end of the superior articular process [2]. The starting site is entered with a high-speed burr. Lateral imaging of the cervical spine is then used to probe and tap the pedicle under radiographic guidance. This is particularly useful for cranial–caudal angulation. Typically, the pedicle is superior to the vertebral endplate at C2–C3, parallel at C3–C4, and inferior to C5–C6 and C6–C7. Additionally, one must be aware of the three dimensionality of the pedicle and ensure adequate medialization in order to avoid lateral perforation that is not seen on lateral fluoroscopic imaging. In general, the medialization angle is between 25° and 45° and is lowest at the C3 level and increases caudally.

The rate of cervical pedicle screw perforation is similar to rates in the lower segments. In five studies that reported rates of screw perforation, they ranged from 6.7 to 30% [2, 29, 41, 54, 55], as compared with 9.9% in the lumbar spine [46]. The most common factor in screw malposition is the level of placement, with more success seen at the more caudal levels. A recent cadaveric study demonstrated that C3 was associated with the highest rate of breach (21%), with decreasing rates of breach at each subsequent level (4% at C6 and C7) [34]. Despite this rate of screw malposition, rates of nerve, spinal cord, and vertebral artery injury are low [35]. Although injury to the vertebral artery is a very uncommon complication (0.3 to 0.5%) of cervical spine surgery, intra-operative management of this injury is crucial to the patient’s clinical outcome. Every attempt should be made to repair the vertebral artery because the contralateral artery may not provide sufficient blood flow in this spondylotic population. If repair is not possible and contralateral circulation is deemed adequate, endovascular coiling or primary ligation should be performed [12]. It should be noted that tamponade alone is ineffective at managing vertebral artery injury and is fraught with many severe complications [9, 10, 14, 30]. Fortunately, studies have found no cerebral ischemia caused by vertebral artery injury, and most of the neurologic deficits seen have been transient in nature [35]. In order to avoid screw perforation and the possibly devastating complications it can cause, one must use intra-operative imaging for guidance. In recent years, intra-operative computed tomography-guided navigation has been proposed as a more accurate method of placing these screws [19, 43, 48]. In a recent retrospective review of three-dimensional CT navigation for placement of pedicle screws in the subaxial cervical spine, the accuracy of screw placement was 93.6% with pre-operative three-dimensional CT navigation and 97.1% with intra-operative three-dimensional CT navigation. There was a 5% overall perforation rate and no neurovascular injury [48].

Discussion

Posterior fusion is a highly effective and safe approach to managing nearly all structural pathology in the subaxial cervical spine. The ultimate goal of each of the mentioned techniques is to provide a stable environment that allows for bony fusion. A noninstrumented onlay technique requires long periods of immobilization and is therefore rarely indicated by itself.

Wiring techniques confer stability by restoring the posterior tension band of the lordotic cervical spine. Because these techniques by themselves may offer inadequate biomechanical strength, they can be augmented with cortical strut graft. Modern instrumentation is achieved by way of screws and rods. Screws may be placed safely in the lateral masses at all levels of the cervical spine. At levels where the lateral mass is compromised, the use of pedicle or translaminar screws may be appropriate.

Translaminar screws are typically only reserved for the more caudal levels, most often at C7, where the lamina can safely accommodate a screw. Pedicle screws provide three-column fixation and are the most biomechanically stable construct. Because of the greater risk of cortical breech, one must consider the use of computed tomography-based intra-operative navigation for placement of pedicle screws in more cranial levels.

Each approach has its own indications and limitations. The surgeon should be aware of them in order to tailor therapy to each unique case. Although complications are rare, they can be severe. It is therefore crucial that the surgeon recognize and manage them intra-operatively.

Electronic Supplementary Material

ESM 1 (1.2MB, pdf)

(PDF 1224 kb)

ESM 2 (1.2MB, pdf)

(PDF 1224 kb)

ESM 3 (1.2MB, pdf)

(PDF 1224 kb)

Compliance with Ethical Standards

Conflict of Interest

Christopher M. Mikhail, MD; James E. Dowdell III, MD; and Andrew C. Hecht, MD, declare that they have no conflicts of interest.

Human/Animal Rights

N/A

Informed Consent

N/A

Required Author Forms

Disclosure forms provided by the authors are available with the online version of this article.

IRB Waiver Statement

The authors of this study did not obtain IRB approval as it does not involve human or animal subjects. Therefore, the study poses no potential risk to individuals and contains no identifiable information. The current study is a review of current concepts on the current literature regarding posterior cervical spinal surgery.

References

  • 1.Abdu WA, Bohlman HH. Techniques of subaxial posterior cervical spine fusions: an overview. Orthopedics. 1992;15(3):287–295. doi: 10.3928/0147-7447-19920301-05. [DOI] [PubMed] [Google Scholar]
  • 2.Abumi K, Kaneda K. Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine. 1997;22(16):1853–1863. doi: 10.1097/00007632-199708150-00010. [DOI] [PubMed] [Google Scholar]
  • 3.Alvin MD, Abdullah KG, Steinmetz MP, et al. Translaminar screw fixation in the subaxial cervical spine: quantitative laminar analysis and feasibility of unilateral and bilateral translaminar virtual screw placement. Spine (Phila Pa 1976) 2012;37(12):E745–E751. doi: 10.1097/BRS.0b013e31824c70ef. [DOI] [PubMed] [Google Scholar]
  • 4.An HS, Gordin R, Renner K. Anatomic considerations for plate–screw fixation of the cervical spine. Spine (Phila Pa 1976) 1991;16(10 Suppl):S548–S551. doi: 10.1097/00007632-199110001-00019. [DOI] [PubMed] [Google Scholar]
  • 5.Anderson PA, Henley MB, Grady MS, Montesano PX, Winn HR. Posterior cervical arthrodesis with AO reconstruction plates and bone graft. Spine (Phila Pa 1976) 1991;16(3 Suppl):S72–S79. doi: 10.1097/00007632-199103001-00012. [DOI] [PubMed] [Google Scholar]
  • 6.Benzel EC, Kesterson L. Posterior cervical interspinous compression wiring and fusion for mid to low cervical spinal injuries. J Neurosurg. 1989;70(6):893–899. doi: 10.3171/jns.1989.70.6.0893. [DOI] [PubMed] [Google Scholar]
  • 7.Cahill DW, Bellegarrigue R, Ducker TB. Bilateral facet to spinous process fusion: a new technique for posterior spinal fusion after trauma. Neurosurgery. 1983;13(1):1–4. doi: 10.1227/00006123-198307000-00001. [DOI] [PubMed] [Google Scholar]
  • 8.Callahan RA, Johnson RM, Margolis RN, Keggi KJ, Albright JA, Southwick WO. Cervical facet fusion for control of instability following laminectomy. J Bone Joint Surg Am. 1977;59(8):991–1002. doi: 10.2106/00004623-197759080-00001. [DOI] [PubMed] [Google Scholar]
  • 9.Choi JW, Lee JK, Moon KS, et al. Endovascular embolization of iatrogenic vertebral artery injury during anterior cervical spine surgery: report of two cases and review of the literature. Spine (Phila Pa 1976) 2006;31(23):E891–E894. doi: 10.1097/01.brs.0000244614.84685.c2. [DOI] [PubMed] [Google Scholar]
  • 10.Cosgrove GR, Theron J. Vertebral arteriovenous fistula following anterior cervical spine surgery. Report of two cases. J Neurosurg. 1987;66(2):297–299. doi: 10.3171/jns.1987.66.2.0297. [DOI] [PubMed] [Google Scholar]
  • 11.Denis F. Spinal instability as defined by the three-column spine concept in acute spinal trauma. Clin Orthop Relat Res. 1984;189:65–76. [PubMed] [Google Scholar]
  • 12.Devin CJ, Kang JD. Vertebral artery injury in cervical spine surgery. Instr Course Lect. 2009;58:717–28. [PubMed] [Google Scholar]
  • 13.Errico T, Uhl R, Cooper P, Casar R, McHenry T. Pullout strength comparison of two methods of orienting screw insertion in the lateral masses of the bovine cervical spine. J Spinal Disord. 1992;5(4):459–463. doi: 10.1097/00002517-199212000-00011. [DOI] [PubMed] [Google Scholar]
  • 14.Garcia Alzamora M, Rosahl SK, Lehmberg J, Klisch J. Life-threatening bleeding from a vertebral artery pseudoaneurysm after anterior cervical spine approach: endovascular repair by a triple stent-in-stent method. Case report. Neuroradiology. 2005;47(4):282–286. doi: 10.1007/s00234-005-1343-2. [DOI] [PubMed] [Google Scholar]
  • 15.Garfin SR, Moore MR, Marshall LF. A modified technique for cervical facet fusions. Clin Orthop Relat Res. 1988;230:149–153. [PubMed] [Google Scholar]
  • 16.Ghori A, Le HV, Makanji H, Cha T. Posterior fixation techniques in the subaxial cervical spine. Cureus. 2015;7(10):e338. doi: 10.7759/cureus.338. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Gill K, Paschal S, Corin J, Ashman R, Bucholz RW. Posterior plating of the cervical spine. A biomechanical comparison of different posterior fusion techniques. Spine (Phila Pa 1976) 1988;13(7):813–816. doi: 10.1097/00007632-198807000-00018. [DOI] [PubMed] [Google Scholar]
  • 18.Grob D, Humke T. Translaminar screw fixation in the lumbar spine: technique, indications, results. Eur Spine J. 1998;7(3):178–186. doi: 10.1007/s005860050053. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Guo F, Dai J, Zhang J, et al. Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine. PLoS One. 2017;12(2):e0171509. doi: 10.1371/journal.pone.0171509. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Hadra B. Wiring the spinous processes in Pott’s disease. Lancet. 1891;138(3564):1408. doi: 10.1016/S0140-6736(02)05049-3. [DOI] [Google Scholar]
  • 21.Heller JG, Carlson GD, Abitbol JJ, Garfin SR. Anatomic comparison of the Roy-Camille and Magerl techniques for screw placement in the lower cervical spine. Spine (Phila Pa 1976) 1991;16(10 Suppl):S552–S557. doi: 10.1097/00007632-199110001-00020. [DOI] [PubMed] [Google Scholar]
  • 22.Heller JG, Silcox DH, 3rd, Sutterlin CE., 3rd Complications of posterior cervical plating. Spine (Phila Pa 1976) 1995;20(22):2442–2448. doi: 10.1097/00007632-199511001-00013. [DOI] [PubMed] [Google Scholar]
  • 23.Hong JT, Sung JH, Son BC, Lee SW, Park CK. Significance of laminar screw fixation in the subaxial cervical spine. Spine (Phila Pa 1976) 2008;33(16):1739–1743. doi: 10.1097/BRS.0b013e31817d2aa2. [DOI] [PubMed] [Google Scholar]
  • 24.Hong JT, Yi JS, Kim JT, Ji C, Ryu KS, Park CK. Clinical and radiologic outcome of laminar screw at C2 and C7 for posterior instrumentation—review of 25 cases and comparison of C2 and C7 intralaminar screw fixation. World Neurosurg. 2010;73(2):112–118. doi: 10.1016/j.surneu.2009.06.010. [DOI] [PubMed] [Google Scholar]
  • 25.Horgan MA, Kellogg JX, Chesnut RM. Posterior cervical arthrodesis and stabilization: an early report using a novel lateral mass screw and rod technique. Neurosurgery. 1999;44(6):1267–1271. [PubMed] [Google Scholar]
  • 26.Jang SH, Hong JT, Kim IS, Yeo IS, Son BC, Lee SW. C7 posterior fixation using intralaminar screws: early clinical and radiographic outcome. J Korean Neurosurg Soc. 2010;48(2):129–133. doi: 10.3340/jkns.2010.48.2.129. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Jeanneret B, Magerl F, Ward EH, Ward JC. Posterior stabilization of the cervical spine with hook plates. Spine (Phila Pa 1976) 1991;16(3 Suppl):S56–S63. doi: 10.1097/00007632-199103001-00010. [DOI] [PubMed] [Google Scholar]
  • 28.Jones EL, Heller JG, Silcox DH, Hutton WC. Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. Spine (Phila Pa 1976) 1997;22(9):977–982. doi: 10.1097/00007632-199705010-00009. [DOI] [PubMed] [Google Scholar]
  • 29.Kast E, Mohr K, Richter HP, Borm W. Complications of transpedicular screw fixation in the cervical spine. Eur Spine J. 2006;15(3):327–334. doi: 10.1007/s00586-004-0861-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Katsaridis V, Papagiannaki C, Violaris C. Treatment of an iatrogenic vertebral artery laceration with the Symbiot self expandable covered stent. Clin Neurol Neurosurg. 2007;109(6):512–515. doi: 10.1016/j.clineuro.2007.02.017. [DOI] [PubMed] [Google Scholar]
  • 31.Kotani Y, Cunningham BW, Abumi K, McAfee PC. Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine. Spine (Phila Pa 1976) 1994;19(22):2529–2539. doi: 10.1097/00007632-199411001-00007. [DOI] [PubMed] [Google Scholar]
  • 32.Liu JK, Das K. Posterior fusion of the subaxial cervical spine: indications and techniques. Neurosurg Focus. 2001;10(4):E7. doi: 10.3171/foc.2001.10.4.8. [DOI] [PubMed] [Google Scholar]
  • 33.Lovely TJ, Carl A. Posterior cervical spine fusion with tension-band wiring. J Neurosurg. 1995;83(4):631–635. doi: 10.3171/jns.1995.83.4.0631. [DOI] [PubMed] [Google Scholar]
  • 34.Luo J, Wu C, Huang Z, et al. The accuracy of the lateral vertebral notch-referred pedicle screw insertion technique in subaxial cervical spine: a human cadaver study. Arch Orthop Trauma Surg. 2017;137(4):517–522. doi: 10.1007/s00402-017-2647-5. [DOI] [PubMed] [Google Scholar]
  • 35.Mahesh B, Upendra B, Mahan RS. The medial cortical pedicle screw—a new technique for cervical pedicle screw placement with partial drilling of medial cortex. Spine J. 2014;14(2):371–380. doi: 10.1016/j.spinee.2013.09.033. [DOI] [PubMed] [Google Scholar]
  • 36.Maki S, Koda M, Iijima Y, et al. Medially-shifted rather than high-riding vertebral arteries preclude safe pedicle screw insertion. J Clin Neurosci. 2016;29:169–172. doi: 10.1016/j.jocn.2015.11.026. [DOI] [PubMed] [Google Scholar]
  • 37.Mascarenhas D, Dreizin D, Bodanapally UK, Stein DM. Parsing the utility of CT and MRI in the subaxial cervical spine injury classification (SLIC) system: is CT SLIC enough? AJR Am J Roentgenol. 2016;206(6):1292–1297. doi: 10.2214/ajr.15.15492. [DOI] [PubMed] [Google Scholar]
  • 38.Maurer PK, Ellenbogen RG, Ecklund J, Simonds GR, van Dam B, Ondra SL. Cervical spondylotic myelopathy: treatment with posterior decompression and Luque rectangle bone fusion. Neurosurgery. 1991;28(5):680–683. doi: 10.1227/00006123-199105000-00007. [DOI] [PubMed] [Google Scholar]
  • 39.Miron RJ, Zhang Q, Sculean A, et al. Osteoinductive potential of 4 commonly employed bone grafts. Clin Oral Investig. 2016;20(8):2259–2265. doi: 10.1007/s00784-016-1724-4. [DOI] [PubMed] [Google Scholar]
  • 40.Nazarian SM, Louis RP. Posterior internal fixation with screw plates in traumatic lesions of the cervical spine. Spine (Phila Pa 1976) 1991;16(3 Suppl):S64–S71. doi: 10.1097/00007632-199103001-00011. [DOI] [PubMed] [Google Scholar]
  • 41.Neo M, Sakamoto T, Fujibayashi S, Nakamura T. The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae. Spine (Phila Pa 1976) 2005;30(24):2800–2805. doi: 10.1097/01.brs.0000192297.07709.5d. [DOI] [PubMed] [Google Scholar]
  • 42.Parker SL, McGirt MJ, Garces-Ambrossi GL, et al. Translaminar versus pedicle screw fixation of C2: comparison of surgical morbidity and accuracy of 313 consecutive screws. Neurosurgery. 2009;64(5 Suppl 2):343–348. doi: 10.1227/01.Neu.0000338955.36649.4f. [DOI] [PubMed] [Google Scholar]
  • 43.Rienmuller A, Buchmann N, Kirschke JS, et al. Accuracy of CT-navigated pedicle screw positioning in the cervical and upper thoracic region with and without prior anterior surgery and ventral plating. Bone Joint J. 2017;99-B(10):1373–1380. doi: 10.1302/0301-620x.99b10.Bjj-2016-1283.R1. [DOI] [PubMed] [Google Scholar]
  • 44.Rogers WA. Fractures and dislocations of the cervical spine; an end-result study. J Bone Joint Surg Am. 1957;39-A(2):341–376. doi: 10.2106/00004623-195739020-00011. [DOI] [PubMed] [Google Scholar]
  • 45.Roy-Camille R, Saillant G, Mazel C, et al. Internal fixation of the unstable cervical spine by a posterior osteosynthesis with plates and screws. In: Sherk HH, Dunn EJ, Eismont FJ, et al., editors. The Cervical Spine. 2. Philadelphia, PA: JB Lippincott; 1989. pp. 390–403. [Google Scholar]
  • 46.Sadrameli SS, Jafrani R, Staub BN, Radaideh M, Holman PJ. Minimally invasive, stereotactic, wireless, percutaneous pedicle screw placement in the lumbar spine: accuracy rates with 182 consecutive screws. Int J Spine Surg. 2018;12(6):650–658. doi: 10.14444/5081. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47.Sawin PD, Traynelis VC, Menezes AH. A comparative analysis of fusion rates and donor-site morbidity for autogeneic rib and iliac crest bone grafts in posterior cervical fusions. J Neurosurg. 1998;88(2):255–265. doi: 10.3171/jns.1998.88.2.0255. [DOI] [PubMed] [Google Scholar]
  • 48.Shimokawa N, Takami T. Surgical safety of cervical pedicle screw placement with computer navigation system. Neurosurg Rev. 2017;40(2):251–258. doi: 10.1007/s10143-016-0757-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49.Shin SI, Yeom JS, Kim HJ, Chang BS, Lee CK, Riew KD. The feasibility of laminar screw placement in the subaxial spine: analysis using 215 three-dimensional computed tomography scans and simulation software. Spine J. 2012;12(7):577–584. doi: 10.1016/j.spinee.2012.07.010. [DOI] [PubMed] [Google Scholar]
  • 50.Watts C, Smith H, Knoller N. Risks and cost-effectiveness of sublaminar wiring in posterior fusion of cervical spine trauma. Surg Neurol. 1993;40(6):457–460. doi: 10.1016/0090-3019(93)90047-5. [DOI] [PubMed] [Google Scholar]
  • 51.White AA, Panjabi MM, et al. Clinical instability of the spine. In: Evarts CM, Burton RI, Cofield RH, et al., editors. Surgery of the Musculoskeletal System. New York, NY: Churchill Livingstone; 1983. pp. 219–244. [Google Scholar]
  • 52.Whitehill R, Stowers SF, Fechner RE, et al. Posterior cervical fusions using cerclage wires, methylmethacrylate cement and autogenous bone graft. An experimental study of a canine model. Spine (Phila Pa 1976) 1987;12(1):12–22. doi: 10.1097/00007632-198701000-00003. [DOI] [PubMed] [Google Scholar]
  • 53.Xu R, Haman SP, Ebraheim NA, Yeasting RA. The anatomic relation of lateral mass screws to the spinal nerves. A comparison of the Magerl, Anderson, and An techniques. Spine (Phila Pa 1976) 1999;24(19):2057–2061. doi: 10.1097/00007632-199910010-00016. [DOI] [PubMed] [Google Scholar]
  • 54.Yoshimoto H, Sato S, Hyakumachi T, Yanagibashi Y, Masuda T. Spinal reconstruction using a cervical pedicle screw system. Clin Orthop Relat Res. 2005;431:111–119. doi: 10.1097/01.blo.0000150321.81088.ab. [DOI] [PubMed] [Google Scholar]
  • 55.Yukawa Y, Kato F, Ito K, et al. Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscope. Eur Spine J. 2009;18(9):12939. doi: 10.1007/s00586-009-1032-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 56.Zhang L, Wang H. Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch. Kaohsiung J Med Sci. 2018;34(12):700–704. doi: 10.1016/j.kjms.2018.08.001. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data