Table 5.
EPs and Incorporated Nanocomposites | wt.% | LOI (%) | UL-94 | pk-HRR (kW/m2) | THR (MJ/m2) | Ref. |
---|---|---|---|---|---|---|
EP | 0 | 21.8 | NR | 781 | 107 | [172] |
EP/DiDOPO | 1 | 24.1 | V-2 | – | – | [172] |
3 | 32.7 | V-0 | – | – | [172] | |
7 | 35.7 | V-0 | 491 | 80 | [172] | |
EP/OMMT | 1 | 22.4 | NR | – | – | [172] |
3 | 23.7 | NR | – | – | [172] | |
7 | 23.7 | NR | 576 | 98 | [172] | |
EP/DiDOPO/OMMT | 0.5/0.5 | 23.2 | NR | – | – | [172] |
1.5/1.5 | 27.1 | V-0 | – | – | [172] | |
3.5/3.5 | 32.2 | V-0 | 369 | 95 | [172] | |
EP | 0 | 21 | – | – | – | [173] |
EP/MMT/MWCNT | 1.5/0.1 | 26.4 | – | – | – | [173] |
EP/Fluorinated MMT | 1.5 | 25.8 | – | – | – | [173] |
EP/Fluorinated MWCNT | 0.1 | 23 | – | – | – | [173] |
EP/Fluorinated MMT/Fluorinated MWMMT | 1.5/0.1 | 31 | – | – | – | [173] |
EP | 0 | 23 | NR | 860 | 112 | [174] |
EP/APP | 10 | 25 | NR | 458 | 62 | [174] |
EP/APP + MMT | 10 | 28 | V-0 | 524 | 50 | [174] |
EP/APP-MMT | 10 | 30 | V-0 | 393 | 34 | [174] |
“NR” means no rating, “–” means no test data.