Skip to main content
. 2020 May 26;19:100360. doi: 10.1016/j.imu.2020.100360

Table 3.

This table reports the number of true and false positives and false negatives for each class.

Fold Network COVID-19
Correct detected
COVID-19
Not detected
COVID-19
Wrong detected
PNEUMONIA
Correct detected
PNEUMONIA
Not detected
PNEUMONIA
Wrong detected
NORMAL
Correct detected
NORMAL
Not detected
NORMAL
Wrong detected

1
Xception 26 5 101 3983 437 569 6245 606 378
ResNet50V2 27 4 96 3858 562 480 6334 517 507
Concatenated 26 5 68 3745 675 309 6526 325 628

2
Xception 23 8 42 3874 546 409 6426 425 528
ResNet50V2 22 9 67 3659 761 501 6340 511 713
Concatenated 23 8 27 3913 507 434 6413 438 492

3
Xception 21 9 28 3942 478 436 6411 440 463
ResNet50V2 22 8 97 3770 650 392 6433 418 587
Concatenated 25 5 35 3847 573 342 6502 349 550

4
Xception 22 9 42 3818 602 433 6411 440 576
ResNet50V2 22 9 78 4015 405 758 6065 786 364
Concatenated 26 5 77 3860 560 480 6340 511 519

5
Xception 21 10 41 4041 379 502 6335 516 362
ResNet50V2 21 10 42 3604 816 284 6549 302 802
Concatenated 24 7 43 3941 479 390 6442 409 462