Table 3.
Univariate analysis of pulmonary function test parameters as risk factors for development of bronchiolitis obliterans syndrome (Odds ratio for each 20% decrease relative to 100% predicted.)
Pre-HCT Parameter | Odds Ratio | 95% CI | P-value |
---|---|---|---|
FEV1 | 1.14 | 0.98–1.31 | 0.09 |
FEF25–75 | 1.13 | 1.03–1.24 | 0.01 |
FVC | 1.05 | 0.91–1.22 | 0.51 |
TLC | 0.92 | 0.78–1.10 | 0.36 |
DLCO | 0.94 | 0.80–1.10 | 0.43 |
Day 80 Parameter | |||
FEV1 | 1.27 | 1.06–1.52 | 0.008 |
FEF25–75 | 1.20 | 1.08–1.34 | <0.001 |
FVC | 1.14 | 0.95–1.36 | 0.17 |
TLC | 0.98 | 0.82–1.16 | 0.78 |
DLCO | 0.94 | 0.79–1.12 | 0.47 |
Abbreviations. FEV1: forced expiratory volume in 1 second; FEF25–75: forced expiratory flow between 25–75% maximum; FVC: forced vital capacity; TLC: total lung capacity; DLCO: diffusing capacity of the lungs for carbon monoxide.