Table 7.

Rapid review contour QA: ROIs with deviations at initial review for patients who required one resubmission (n = 80)

ROI Failure mode n %*

PTV boost eval (missing, n = 2) Deviation unacceptable 23 29.5
Breast PTV eval Deviation unacceptable 20 25.0
CTV boost Deviation unacceptable 17 21.3
PTV boost (missing, n = 2) Deviation unacceptable 15 19.2
Breast CTV Deviation unacceptable 15 18.8
Breast PTV (missing, n = 1) Deviation unacceptable 10 12.7
Thyroid (missing, n = 3) Deviation unacceptable 8 10.4
Contralateral breast (missing, n = 1) Deviation unacceptable 5 6.3
Surgical bed (missing, n = 2) Deviation unacceptable 4 5.1
Heart (missing, n = 1) Deviation unacceptable 3 3.8
Ipsilateral lung (missing, n = 1) Deviation unacceptable 1 1.3

Abbreviations: PTV = planning target volume; ROI = region of interest; QA = quality assurance.

*

Denominator is 80 unless there are missing values, in which case denominator = 80 – missing.

Added during second protocol amendment.