Comparison of analytical performance (linear range and LOD) of the different nano biosensing systems for detection of HTLV-1.

Detection Method Strategy Limit of Detection Linear Range Ref.
Electrochemical Differential Pulse Voltammetry (DPV) Self-assembly of DNA on Au NPs and magnetic separation 1.7 pM 44 pM–2 nM [50]
Optical Fluorescence CdTe modified DNA probes 1.95 pg/μl 10 pg/μl – 0.24 ng/μl [60]
FRET between CDs and Fe3O4@Au NPs 10 nM 10–320 nM [69]
CdTe QDs tagged complementary DNA probe 10 pg/ml 10 pg/ml – 21 ng/ml [70]
Hairpin shaped probe tagged with AG NCs 8.5 nM 10–200 nM [75]
Photoelectrochemical Cascade photoactive materials and triple helix molecular switch 0.65 fM 1 fM – 1 nM [115]