. 2020 May 30;180:107008. doi: 10.1016/j.buildenv.2020.107008

Table 2.

Cases tested for the two scenarios.

Test series Case label PVa(L/s) PVb(L/s) MVa(ACRb) uP1,NMc (m/s) uP1,TMd (m/s)
Baseline case MV 0 0 2








0 0
PV used for manikin A only PVa3 3 0 1.14 0.56
PVa6 6 0 2.28 1.40
PVa9 9 0 3.48 2.19
PV used for manikin B only PVb3 0 3 0 0
PVb6 0 6 0 0
PVb9 0 9 0 0
PV used for both manikin A and B PVab3 3 3 1.14 0.56
PVab6 6 6 2.28 1.40
PVab9 9 9 3.48 2.19
a

MV: mixing ventilation.

b

ACR: air change rate.

c

uP1,NM is the PV centerline velocity of a free nozzle jet at P1 (the distance between the nozzle and P1 is 0.36 m) with Manikin A absent (NM), which was measured using a hot wire anemometer (Swema 03+).

d

uP1,TM is the PV centerline velocity at P1 with Manikin A present (TM), which was extrapolated from Fig. 6 in Ref. [23].