Skip to main content
. 2020 Jun 1;6(2):00356-2019. doi: 10.1183/23120541.00356-2019

TABLE 1.

Baseline characteristics by tertiles (T) of skin autofluorescence (n=4111)

T1, 1.0–1.8 AU T2, 1.9–2.1 AU T3, 2.2–4.6 AU p-value
Subjects 1480 1345 1286
Age years 56.8±4.3 57.5±4.1 58.4±4.3 <0.001
Females 55.5% 53.6% 50.7% 0.011
Height cm 171.8±9.9 171.7±9.6 170.9±9.7 0.020
Weight kg 79.9±15.7 80.1±15.4 80.9±16.9 0.087
Smoking
 Current 9.7% 15.9% 26.1% <0.001
 Former 38.5% 41.0% 41.0%
 Never 51.8% 43.0% 32.9%
eGFR mL·min−1·1.73 m−2 82.9±15.3 82.7±14.3 82.7±16.6 0.643
Diabetes 5.4% 6.5% 13.3% <0.001
COPD 1.5% 1.6% 3.3% 0.009
HbA1c mmol·mol−1 geometric mean 35.9 36.0 37.5 <0.001
Plasma glucose mmol·L−1 geometric mean 5.38 5.43 5.58 <0.001
CRP mmol·L−1 geometric mean 1.3 1.4 1.6 <0.001
FEV1 L 3.25±0.76 3.21±0.80 3.06±0.76 <0.001
FEV1 % predicted 94.9±11.6 94.2±12.4 92.2±12.9 <0.001
FVC L 4.13±0.99 4.09±1.0 3.94±0.94 <0.001
FVC % predicted 97.7±12.7 96.6±14.1 93.6±14.7 <0.001
FEV1/FVC 0.790±0.06 0.785±0.06 0.779±0.07 <0.001
DLCO % predicted 90.9±12.6 89.8±13.6 86.9±14.6 <0.001
DLCO/VA % predicted 97.0±13.5 96.1±14.1 94.6±15.8 <0.001
R5 % predicted 106.9 (93.3–125.6) 107.7 (92.1–127.8) 108.6 (93.3–127.3) 0.312
R20 % predicted 128.6±31.3 128.5±31.1 128.2±31.2 0.766
R5R20 % predicted 54.9 (24.0–91.9) 55.9 (23.1–93.4) 63.3 (29.4–99.9) 0.667
X5 % predicted 87.2 (68.1–108.9) 88.1 (68.5–110.0) 89.6 (71.1–114.6) 0.001
AX % predicted 60.6 (38.3–97.0) 61.8 (39.5–101.6) 65.2 (39.7–112.6) 0.348
fres % predicted 79.2 (68.8–95.1) 80.4 (69.3–95.9) 82.3 (68.9–98.6) <0.001

Data are presented as mean±sd or median (interquartile range), unless otherwise stated. Diffusing capacity parameters: % predicted values calculated for 3889 subjects (T1, n=1408; T2, n=1273; T3, n=1208). Impulse oscillometry parameters: % predicted values presented for 3970 subjects (T1, n=1433; T2, n=1298; T3, n=1239). p-value: ANOVA or Chi-squared for test of linearity for continuous and categorical variables, respectively. Mean values of X5 in T1–T3 of SAF are: T1, −0.089 kPa·L−1·s; T2, −0.092 kPa·L−1·s; T3, −0.097 kPa·L−1·s. Higher % predicted values of impulse oscillometry measures reflect an impairment in lung function. eGFR: estimated glomerular filtration rate; HbA1c: glycated haemoglobin; CRP: C-reactive protein; FEV1: forced expiratory volume in 1 s; FVC: forced vital capacity; DLCO: diffusing capacity of the lung for carbon monoxide; VA: alveolar volume; R5: resistance measured at 5 Hz; R20: resistance measured at 20 Hz; X5 reactance measured at 5 Hz; AX: area of reactance; fres: resonant frequency.