Skip to main content
. 2020 Jun 1;6(2):00356-2019. doi: 10.1183/23120541.00356-2019

TABLE 4.

Change in impulse oscillometry (IOS) measures per 1-sd increase in skin autofluorescence (SAF) (n=3970)

Change in IOS measure per 1-sd increase in SAF (95% CI) p-value
R5 kPa·L−1·s Model 1 0.003 (0.00–0.006) 0.044
Model 2 −0.001 (−0.003–0.002) 0.628
R20 kPa·L−1·s Model 1 0.00 (−0.002–0.003) 0.732
Model 2 −0.001 (−0.003–0.001) 0.337
R5R20 kPa·L−1·s Model 1 0.002 (0.001–0.004) 0.002
Model 2 0.00 (−0.001–0.002) 0.509
AX kPa·L−1 Model 1 0.020 (0.009–0.031) 0.001
Model 2 0.006 (−0.003–0.015) 0.229
fres Hz Model 1 0.253 (0.150–0.357) <0.001
Model 2 0.100 (−0.002–0.199) 0.054
X5 kPa·L−1·s Model 1 −0.003 (−0.004– −0.002) 0.001
Model 2 −0.001 (−0.003– −0.00006) 0.042

Model 1 adjusted for age, height and sex. Model 2 adjusted for age, height, sex, weight, smoking status (never-, ex- and current smokers), pack-years, estimated glomerular filtration rate, diabetes, log(glycated haemoglobin), log(plasma glucose) and log(C-reactive protein). R5: resistance measured at 5 Hz; R20: resistance measured at 20 Hz; AX: area of reactance; fres: resonant frequency; X5: reactance measured at 5 Hz.