TABLE 3.
Diagnostic Accuracies of Different Imaging Parameters for Detection of PTEN Status
| Variable | AUC | Cutoff | Sensitivity | Specificity |
| Per-patient analysis | ||||
| ADCmean (μm2/s) | 0.56 (0.29–0.84) | 577 | 0.78 | 0.56 |
| PI-RADS score (3/4/5) | 0.58 (0.47–0.70) | 4 | 0.62 | 0.56 |
| Maximum diameter (cm) | 0.62 (0.46–0.79) | 1.25 | 0.73 | 0.56 |
| SUVmax | 0.84 (0.73–0.94) | 10.3 | 0.80 | 0.77 |
| Per-lesion analysis | ||||
| ADCmean (μm2/s) | 0.53 (0.25–0.82) | 577 | 0.75 | 0.58 |
| PI-RADS score (3/4/5) | 0.62 (0.50–0.75) | 4 | 0.59 | 0.58 |
| Maximum diameter (cm) | 0.68 (0.55–0.81) | 1.25 | 0.78 | 0.53 |
| SUVmax | 0.88 (0.91–0.95) | 10.3 | 0.83 | 0.74 |
AUC = area under curve; PI-RADS: Prostate Imaging Reporting and Data System; maximum diameter = maximum diameter of lesion on MRI.
Data in parentheses are 95% CIs.