Skip to main content
. 2020 Jun 2;10:8967. doi: 10.1038/s41598-020-65824-1

Figure 2.

Figure 2

Large-caliber axons are selectively degraded in mdx mice (a) Fiber diameters (axon plus myelin diameter) in wildtype mice (phrenic: 8.08 μm ± 0.10; XII: 6.76 μm ± 0.11; n = 200 fibers) and mdx mice (phrenic: 7.58 μm ± 0.07; XII: 6.21 μm ± 0.08; n = 300 fibers). Phrenic: p = 1.96 x 10−5 Two Sample t-test; XII: p = 3.78 x 10−5 Mann-Whitney U test. (b) Axon diameter values in wildtype mice (phrenic: 5.81 μm ± 0.08; XII: 4.76 μm ± 0.10; n = 200 axons) and mdx mice (phrenic: 5.39 μm ± 0.06; XII: 4.32 μm ± 0.07; n = 300 axons). Phrenic: p = 1.80 ×10−5 Two Sample t-test; XII: p = 9.52 ×10−5 Mann-Whitney U test. (c) Distribution of fiber diameters in wildtype mice (phrenic SD: 1.41 μm; XII SD: 1.60 μm) and mdx mice (phrenic SD: 1.18 μm; XII SD: 1.44 μm). (d) Distribution of axon diameters in wildtype mice (phrenic SD: 1.16 μm; XII SD: 1.37 μm) and mdx mice (phrenic SD: 0.10; XII SD: 1.26 μm). (e) Cumulative proportion plots of fiber areas. (f) Cumulative proportion plots of axon areas. (g,h) Brightfield images of nerve cross sections. Black arrows indicate normal-sized axons, while red arrows point to smaller axons. Scale bars represent 10 μm.