Skip to main content
. 2020 Mar 27;152(6):e201912506. doi: 10.1085/jgp.201912506

Table 2. Results of changing individual parameters in Scheme 1 to account for effects of NS11021.

Parameter Fit A Fit B
Value at 30 µM NS11021 χ2 Value at 30 µM NS11021 χ2
J0 0.32 1.96 0.36 2.53
KD (µM) 6.8 11.8 2.9 11.29
L0 8.7 × 10−5 2.16 2.1 × 10−4 3.77
zJ (e0) 0.82 11.35 1.3 9.14
zL (e0) 1.8 11.52 2.0 12.09
C 6.0 10.40 35 11.66
D 74 2.37 61 1.56
E 5.0 9.46 5.1 9.86

Simultaneous (global) fitting was performed using G–V relations acquired over a range of Ca2+ for [NS11021] at 0, 0.1, 1, 10, and 30 µM, with parameters shown above adjusted individually, as described in Materials and methods. Adjusted parameter values at 30 µM NS11021 are shown above, along with summed χ2 values for fitting over the entire range of [NS11021] and [Ca2+] (based on 410 experimental data points). Unadjusted parameter values (corresponding to 0 µM NS11021) can be found in Table 1. The bold values emphasize the parameters L0, J0, and D that, when changed, provided nearly equal descriptions of the experimental G-V-Ca2+ relations.