COVID‐19 RT‐PCR test results interpretation

SARS‐CoV‐2 N1 SARS‐CoV‐2 N2 SARS‐CoV‐2 N3 RNase P Result interpretation Report
+ + + +/− SARS‐CoV‐2 detected Positive
+ + +/− +/− SARS‐CoV‐2 detected Positive
+ +/− +/− SARS‐CoV‐2 detected Positive
+ +/− +/− SARS‐CoV‐2 detected Positive
+ +/− Sample is again repeated. If the result remains the same, additional confirmatory testing is conducted Presumptive positive
+ SARS‐CoV‐2 not detected Negative
Sample is again repeated. If a second failure occurs, another sample is taken. Invalid