Skip to main content
. 2020 Jun 3;19:59. doi: 10.1186/s12940-020-00612-y

Table 2.

Distribution of indoor air pollution concentrations in 617 houses in Peru, by site and use of biomass cookstoves

Lima Tumbes Puno City Puno Rural All Biomass Users All Non-biomass Users
N or
Mean (SD)
N or
Mean (SD)
N or
Mean (SD)
N or
Mean (SD)
N or
Mean (SD)
N or
Mean (SD)
Number of households 105 92 166 254
PM2.5μg/m324-h means
 Mean (SD) 42.8 (12.4) 37.6 (12.1) 16.3 (10.3) 99.6 (102.0) 92.1 (98.1) 29.2 (20.5)
 Geometric mean (GSD) 41.1 (1.3) 35.8 (1.4) 14.1 (1.7) 58.8 (3.1) 55.0 (2.9) 23.7 (2.0)
 Daily hours > 25 μg/m3 20.7 (4.3) 18.3 (6.2) 3.6 (3.1) 5.0 (3.1) 6.5 (5.8) 11.6 (9.1)

 Spearman correlation:

Daily mean vs. hrs. >  25 μg/m3

0.87 0.82 0.91 0.59 0.47 0.95
CO ppm 24-h means
 Mean (SD) 1.3 (0.9) 0.9 (0.6) 1.9 (3.2) 12.1 (17.9) 10.8 (17.2) 1.5 (2.4)
 Geometric mean (GSD) 1.0 (2.0) 0.8 (1.6) 1.2 (2.3) 4.9 (4.3) 4.0 (4.4) 1.0 (2.1)
 Daily hours > 5.68 ppm 0.2 (0.5) 0.3 (0.9) 1.3 (2.6) 6.0 (6.7) 5.4 (6.6) 0.8 (1.9)

Spearman correlation:

Daily mean vs. hrs. >  5.68 ppm

0.51 0.49 0.91 0.92 0.93 0.73