. 2020 May 28;11:366. doi: 10.3389/fneur.2020.00366

Table 5.

Technical characteristics of the studies included in the SWI meta-analysis.

References Technical aspects
Magnetic field Vendor Method ROIs drawn in Voxel size (mm3)
Gupta et al. (45) 1.5 T Siemens Hypointensity scores SWI N/A
Zhang et al. (49) 3 T Siemens Phase shift Phase images 0.5 × 0.5
Jin et al. (50) 3 T GE Phase values Phase images 0.8 × 0.9 × 2
Lotfipour et al. (51) 7 T Philips Relative susceptibility Modulus images and then applied to SWI Protocol A: 0.7 × 0.7 × 0.7
Protocol B 0.4 × 0.4 × 0.5
Wang et al. (46) 1.5 T Siemens Phase shift Phase images 0.5 × 1 × 2
Rossi et al. (23) 3 T Siemens SWI contrast Phase images 0.9 × 0.9 × 1.5
Wang et al. (47) 3 T GE Phase values Phase images 0.5 × 0.8 × 2
Wu et al. (48) 3 T Philips Phase values Phase images 0.5 × 0.6 × 1.5
Isaias et al. (12) 3 T Philips Phase values Phase images 1 × 1 × 1
Martin-Bastida et al. (52) 3 T Siemens Phase shift Phase images N/A