Table 1.
Instrument handling | Tissue handling | Errors | ||||
---|---|---|---|---|---|---|
A | B | A | B | A | B | |
Pickup needle in correct orientation | 2.7 (0.8) | 2.6 (0.8) | 2.4 (0.6) | 2.3 (0.7) | 0.9 (2.0) | 0.9 (2.3) |
Pass needle through edges of tissue | 2.5 (0.7) | 2.5 (0.8) | 2.3 (0.7) | 2.3 (0.8) | 0.5 (0.9) | 0.5 (0.8) |
Create first double throw | 2.3 (0.8) | 2.4 (0.9) | 2.3 (0.7) | 2.3 (0.6) | 0.2 (0.4) | 0.1 (0.3) |
Knot tying | 2.5 (0.9) | 2.4 (0.8) | 2.4 (0.7) | 2.3 (0.7) | 0.5 (0.6) | 0.4 (0.5) |
Total score | 10.0 (2.8) | 9.9 (3.0) | 9.4 (2.3) | 9.1 (2.4) | 2.1 (3.2) | 1.9 (3.2) |
A observer A, B observer B