Skip to main content
. 2020 May 9;10(5):292. doi: 10.3390/diagnostics10050292

Table 7.

Accuracy (%) with (95% CI) for detecting stress and non-stress, and evaluating stress levels using each frontal electrode individually using five-folds cross validation.

Classifier Fp1 Fp2 F3 F4 FZ F7 F8
Detection of Stress and Non-stress
KNN 99.74
(99.70–99.78)
99.54
(99.49–99.59)
99.37
(99.35–99.39)
97.82
(97.77–97.86)
99
(98.98–99.08)
99.29
(99.21–99.37)
98.87
(98.93–99.02)
Cubic SVM 99.64
(99.63–99.65)
99.39
(99.35–99.43)
99.18
(99.14–99.22)
97.78
(97.73–97.84)
99.22
(99.20–99.25
99.14
(99.09–99.19)
99
(98.99–99.07)
Evaluating Stress Levels
KNN 92
(91.71–92.29)
90
(89.82–90.34)
90.74
(90.32–91.16)
85.58
(85.32–85.85)
88.76
(87.96–89.56)
91.36
(90.92–91.79)
92.5
(92.18–92.82)
Cubic SVM 88.48
(88.06–88.89)
88.48
(88.21–88.75)
88.62
(88.07–89.17)
87.3
(87.0–87.59)
89.58
(89.29–89.87)
92.26
(91.89–92.63)
90.98
(90.60–91.36)