Skip to main content
. 2020 Feb 8;5(3):473–481. doi: 10.1016/j.adro.2020.01.005

Table 2.

Lesion detection and segmentation results

Training Evaluation DSC of detection Agreement Sens. Spec.
45 public patients 10 public validation patients 0.62 ± 0.17 80% 0.55 ± 0.30 0.974 ± 0.010
23 public testing patients 0.59 ± 0.14 87% 0.63 ± 0.28 0.964 ± 0.015
42 private testing patients 0.38 ± 0.19 47% 0.22 ± 0.24 0.972 ± 0.015
45 public patients + 21 private patients 10 public validation patients 0.64 ± 0.11 90% 0.57 ± 0.23 0.980 ± 0.009
23 public testing patients 0.56 ± 0.15 83% 0.50 ± 0.28 0.969 ± 0.016
21 private testing patients 0.46 ± 0.15 63% 0.33 ± 0.17 0.977 ± 0.013

Abbreviations: DSC = dice similarity coefficient; Sens. = sensitivity; Spec = specificity.