Skip to main content
. 2020 May 8;24:23–31. doi: 10.1016/j.jot.2020.04.004

Table 1.

Parameters for MRI of rhesus monkeys and humans.

Parameter T1-weighted T2-weighted T1 ρ∗ T2 map
Pulse sequence TSE TSE TSE TSE
Monkey
 Repetition time (ms) 400 2500 800 2000
 Echo time (ms) 7.8 100 8 TE∗∗
 Field of view (mm) 210 × 210 210 × 210 210 × 210 210 × 210
 Pixel bandwidth (Hz) 242 475 332 234
 Voxel size (mm) 0.9 × 1.25 0.9 × 1.25 0.59 × 1.17 0.7 × 0.8
 Section thickness (mm) 3 3 3 3
 Section gap (mm) 0 0 0 0
 Number of sections 7 7 4 × 7 8 × 7
 Turbo factor 4 45 12 8
 Acquisition time (ms) 140 80 451 526
Human
 Repetition time (ms) 448 3228 800 2000
 Echo time (ms) 8 100 8 TE∗∗
 Field of view (mm) 250 × 250 250 × 250 240 × 240 240 × 240
 Pixel bandwidth (Hz) 320 348 348 234
 Voxel size (mm) 0.9 × 1.25 0.9 × 1.25 0.59 × 1.17 0.7 × 0.8
 Section thickness (mm) 3 3 3 3
 Section gap (mm) 0 0 0 0
 Number of sections 15 15 4 × 16 8 × 16
 Turbo factor 4 45 12 8
 Acquisition time 208 160 260 526

∗Time of spin locking at 2, 15, 30, and 45 ms.

∗∗Time of spin locking at 11, 22, 32, 43, 54, 65, 76, and 85 ms.

MRI = magnetic resonance imaging; TSE = turbo spin echo; TE = the echo time.