Skip to main content
. Author manuscript; available in PMC: 2020 Jun 9.
Published in final edited form as: Water Res. 2017 Jun 22;123:183–191. doi: 10.1016/j.watres.2017.06.064

Fig. 8.

Fig. 8.

Arsenic removal in water by oxidized aquifer material achieved through passive air exposure (AE) and oven-dried (OD) aquifer samples. Arsenic loss (%) was calculated ([As]INITIAL - [As]FINAL)/[As]INITIAL) × 100) and based on samples collected 68 days after the arsenic solution ([As]INITIAL = 550 μg/L) was amended to the test reactors. All samples (replicates) in AE and OD reactors were non-detect (detection limit = 5 μg/L).