Parameter identification—experiments. Bold values indicate changes in process conditions. Note the different units compared to the nomenclature. They were used in this table for better readability of the numbers.

Time m˙p m˙l  Ta,in V˙ameas tdry
hh:mm kg/h g/min °C m3/h s
10:02–10:20 20 40 50 300 680
10:20–10:28 20 40 50 300 580
10:28–11:00 20 40 45 300 580
11:00–11:39 20 40 45 300 480
11:39–12:33 20 40 45 400 580
12:33–12:56 20 40 45 400 480