Skip to main content
. 2020 May 16;20(10):2838. doi: 10.3390/s20102838

Table 7.

Performance comparison for the vessel segmentation using DRIVE.

Method Accuracy Sensibility Specificity
SegNet_Vgg16 (proposed) 0.937 0.842 0.938
Palomera-Perez et al. [32] 0.925 0.640 0.967
Vlachos et al. [33] 0.929 0.749 0.955
Espona et al. [34] 0.935 0.743 0.962
Soomro et al. [35] 0.948 0.739 0.956