Results of fatigue modified beam tests.

Specimen Bonded Length (mm) Bonded Width (mm) σmin (MPa) σmax (MPa) NF (106)
MB_300_60_B_F_1 300 60 550 1050 0.20
MB_300_60_B_F_2 300 60 550 1050 0.47
MB_300_60_B_F_3 300 60 550 1050 1.22

Bonded length of each side of the specimen (Figure 3).