Skip to main content
. 2020 May 19;13(10):2329. doi: 10.3390/ma13102329

Table 2.

Energy absorption values of AMFs according to loading direction and testing temperature.

Loading
Direction
TT
[°C]
Energy Absorption at Different Strains [MJ/m3]
10% 20% 30% 40% 50% 60% 70%
X-LD −196 0.87 1.46 2.33 3.14 3.92 4.92 5.97
25 0.52 1.01 1.63 2.31 2.93 3.59 4.45
250 0.36 0.70 1.13 1.55 1.99 2.54 3.37
Y-LD −196 0.76 1.23 1.90 2.69 3.45 4.20 5.11
25 0.40 0.71 1.17 1.64 2.37 2.53 3.09
250 0.33 0.65 1.08 1.49 1.92 2.34 3.02
Z-LD −196 0.78 1.34 2.18 3.01 3.90 4.89 5.87
25 0.49 0.94 1.50 2.05 2.63 3.23 4.10
250 0.35 0.68 1.10 1.51 1.95 2.41 3.15