Skip to main content
. 2020 May 26;5(22):12789–12808. doi: 10.1021/acsomega.0c00423

Table 3. Mechanical Properties of 100i-PP and i-PP/ECR Blends in the Absence and Presence of the E-AE-MA-TP Compatibilizer.

sl. no. sample code ultimate tensile strength (MPa) strain at break (%) stress at 100% strain (MPa) tension set (%)
1 100i-PP 35.5 ± 1.5 14 ± 5    
2 50i-PP/50ECR 17.3 ± 1.5 31 ± 5    
3 40i-PP/60ECR 13.8 ± 1.0 46 ± 7    
4 30i-PP/70ECR 10.8 ± 1.0 62 ± 8   54 ± 1
5 20i-PP/80ECR 6.1 ± 0.5 96 ± 4    
6 40i-PP/60ECR/3C 15.2 ± 1.0 270 ± 12 14.3 ± 1.0  
7 40i-PP/60ECR/5C 17.2 ± 1.0 370 ± 12 15.4 ± 1.0 18 ± 1
8 40i-PP/60ECR/7C 16.1 ± 1.0 310 ± 10 14.8 ± 1.0  
9 30i-PP/70ECR/3C 13.2 ± 1.0 190 ± 12 12.8 ± 1.0  
10 30i-PP/70ECR/5C 14.5 ± 1.0 270 ± 12 14.5 ± 1.0 20 ± 1
11 30i-PP/70ECR/7C 13.8 ± 1.0 230 ± 10 13.2 ± 1.0