Table 2. Impedance Parameters Derived from Plots for Copper in Acid Rain Soultion and with the Addition of 1 × 10–3 mol/dm3 5Cl-BTA.
| inhibitor, mol/dm3 | Rs, Ω cm2 | Rf, Ω cm2 | Rct, Ω cm2 | W, Ω–1 cm–2 s0.5 | Cf, μF cm–2 | n1 | Cdl, μF cm–2 | n2 | IE, % |
|---|---|---|---|---|---|---|---|---|---|
| 167.2 | 400.6 | 500.4 | 32 | 7.30 × 10–7 | 0.7279 | 3.82 × 10–6 | 0.665 | ||
| 1 × 10–3 | 176 | 8923 | 129.1 | 1660 | 5.16 × 10–8 | 0.857 | 1.08 × 10–6 | 0.71 | 90.05 |