Skip to main content
. 2020 May 29;5(22):12832–12841. doi: 10.1021/acsomega.0c00553

Table 2. Impedance Parameters Derived from Plots for Copper in Acid Rain Soultion and with the Addition of 1 × 10–3 mol/dm3 5Cl-BTA.

inhibitor, mol/dm3 Rs, Ω cm2 Rf, Ω cm2 Rct, Ω cm2 W, Ω–1 cm–2 s0.5 Cf, μF cm–2 n1 Cdl, μF cm–2 n2 IE, %
  167.2 400.6 500.4 32 7.30 × 10–7 0.7279 3.82 × 10–6 0.665  
1 × 10–3 176 8923 129.1 1660 5.16 × 10–8 0.857 1.08 × 10–6 0.71 90.05